Skip to main content

SP POWERWORLD ADVR-16-400Hz

AVR Compatible with Marelli, Basler and Caterpillar Models

The ADVR-16-400Hz Analog Digital 16 Amp Voltage Regulator can be used in a Genset parallel operation and is Compatible with many Marelli, SIEMENS and Kato models.

Ex stock - shipped Worldwide. For GBP, EURO or USD pricing please contact us:

Sales: james.daff@sp-powerworld.com

Office: info@sp-powerworld.com

Tel: +44 (0)115 923 2568 (United Kingdom)

Tel: (24-hour) +44 (0)7484709956 (United Kingdom)

Manual

Features

* Voltage Regulation < ±0.5% * Suitable for brushless type generator Sensing Input 170~510 VAC * Can be used in Parallel Operation * 16 ADC Current Output * EA16 Suitable Frequency 50/60 Hz , EA16-400Hz Suitable Frequency 400 Hz * Soft Start Voltage Ramping * Load CT Current Compensation, Analogue Voltage Input

Specifications

Model NO. EA16 EA16-400Hz
Sensing Input Voltage 170~510 VAC single phase 2 wire Voltage 170~510 VAC single phase 2 wire
Frequency 50/60 Hz Frequency 400 Hz
Power Input Voltage 60~300 VAC single phase 2 wire Voltage 60~300 VAC single phase 2 wire
Max. 90 VDC @ 240 VAC input
Output Voltage Max. 90 VDC @ 240 VAC input
Current Continuous 16A, Max. Intermittent 20A for 10 sec.
Resistance Min. 6 Ohm @ 35 VDC
Voltage Max. 90 VDC @ 240 VAC input
Current Continuous 16A, Max. Intermittent 20A for 10 sec.
Resistance Min. 6 Ohm @ 35 VDC
Voltage Regulation < ±0.5% (with 4% engine governing) < ±0.5% (with 4% engine governing)
Voltage Build-up Residual volts at AVR terminal > 5 VAC Residual volts at AVR terminal > 5 VAC
External Volts Adjustment ±5% with 2 K Ohm 1 watt trimmer ±5% with 2 K Ohm 1 watt trimmer
Unit Power Dissipation Max. 10 watt Max. 10 watt
Thermal Drift 0.03% per °C change in AVR ambient 0.03% per °C change in AVR ambient
Under Frequency Protection 55 Hz @ 60 Hz / 45 Hz @ 55 Hz (Adjustable) 360 Hz (Adjustable)
CT Current Compensation Input 1A or 5A (Selectable) 1A or 5A (Selectable)
Analogue Input ±5 VDC ±10% AC @ ±3 VDC ±5 VDC ±10% AC @ ±3 VDC
Environment Operating Temperature : -40~70 °C
Storage Temperature : -40~85 °C
Relative Humidity : Maximum 95%
Vibration : 3.3G @ 100~2 KHz
Operating Temperature : -40~70 °C
Storage Temperature : -40~85 °C
Relative Humidity : Maximum 95%
Vibration : 3.3G @ 100~2 KHz
AVR Controls Functions VOLT : Voltage Adjustment
STAB : Stability Adjustment
U/F*: To Set the U/F Knee Point
DROOP : To Adjust Droop
TRIM : Analogue Input Adjustment
(*U/F: Under Frequency Protection)
VOLT : Voltage Adjustment
STAB : Stability Adjustment
U/F*: To Set the U/F Knee Point
DROOP : To Adjust Droop
TRIM : Analogue Input Adjustment
(*U/F: Under Frequency Protection)
Dimensions 156.0 (L) x 106.0 (W) x 43.0 (H) mm 156.0 (L) x 106.0 (W) x 43.0 (H) mm
Weight 450 g ±2% 450 g ±2%
<p class="anno2">*Note : All features &amp; specifications subject to change without notice.</p>

Dimensions